Waterproof pressure sensors for sewage treatment gates require stable pressure and level measurement under wet, dirty, and corrosive conditions. Typical technical parameters include measuring ranges of 0-1 bar, 0-5 bar, or 0-10 bar; overload capacity of 150% FS; accuracy of +/-0.5% FS; and long-term stability of +/-0.2% FS/year. The measuring principle is piezoresistive with a flush 316L stainless steel or PVDF diaphragm. The housing is IP68 rated for continuous immersion, and the wetted parts resist sewage, sludge, and mild chemicals. Output options include 4-20 mA, 0-10 V, and RS485 Modbus. Power supply is 12-36 VDC, with reverse-polarity and surge protection. Process connections include G1/2, G1/4, or flange mounting. The shielded PUR cable is available in 5-20 m lengths. Operating temperature is -20 C to 80 C, with a compensated range of 0 C to 60 C. Response time is <=10 ms, insulation resistance is >=100 MOhm, and EMC performance meets industrial requirements. The sensor should also provide lightning protection, 1.5x FS burst pressure, <=0.1% FS repeatability, and 10 million pressure cycles. For gate applications, a flush diaphragm, anti-clogging design, breathable waterproof cable, and corrosion-resistant body prevent debris blockage and ensure stable gate control, alarm output, and SCADA integration. Optional features include an LCD display, HART, Modbus RTU, and M20 x 1.5 cable entry; weight is about 0.6 kg. Before installation, confirm the range, medium compatibility, cable outlet, and calibration certificate.