Port stacker-reclaimers in dusty, potentially explosive bulk terminals need precise motion control and robust explosion protection. The intrinsically safe explosion-proof crane and trolley positioning model uses IS sensors, flameproof enclosures, and redundant encoders to monitor long travel, trolley travel, and hoist motion. A typical model, IS-EP-CP300, specifies ±10 mm positioning accuracy, ±5 mm repeatability, IP66 protection, Ex ib IIC T4 Gb / Ex tb IIIC T130°C Db rating, and -20°C to +55°C operation. Its trolley positioning subsystem combines dual absolute encoders, laser distance sensors, and mechanical limit switches. Signal circuits remain intrinsically safe, while power and motor circuits adopt flameproof or increased-safety designs. The specification requires CANopen/Modbus TCP communication, 24 VDC IS interfaces, galvanic isolation, surge protection, and self-diagnosis. Coded rail strips or RFID tags provide reference calibration. The controller fuses encoder, laser, and limit data to prevent skew, collision, and overtravel. Installation follows IEC 60079 and port EMC rules. Commissioning covers explosion-proof inspection, zero calibration, accuracy verification, and fail-safe testing. This model improves safety, repeatability, and maintenance efficiency in coal, grain, and chemical ports. The model supports redundant controllers, anti-sway control, and remote diagnostics. Acceptance tests cover Ex inspection, zero calibration, positioning accuracy, and fail-safe checks.