An explosion-proof turbine flowmeter at a mixing station storage tank is critical for accurate additive dosing and safe transfer. When it fails, operators may see no pulse output, unstable readings, low flow alarms, or batch errors. Common causes include contaminated product, worn bearings, damaged turbine blades, moisture in the connector, loose grounding, and incorrect K-factor settings. In hazardous areas, never open the meter unless the line is isolated, depressurized, and gas-tested. First check the display, power supply, wiring continuity, and shielding. Compare indicated flow with a proven reference method. Remove the sensor only after safe isolation; inspect the rotor for friction, debris, or magnetic particles. Clean with a compatible solvent and replace damaged bearings or blades. Verify explosion-proof seals, cable glands, and grounding resistance. Confirm the K-factor and signal output against the calibration certificate. For sticky fluids, flush the line and review filtration. If pulses stop intermittently, inspect terminal tightness and moisture ingress. After repair, leak-test, purge, and recalibrate before returning to service. A scheduled inspection plan, spare parts control, and operator training reduce downtime and prevent unsafe repairs. Check cable entry seals and confirm the hazardous-area certification matches the installed environment. Record fault codes and flow trends to identify repeat issues and plan predictive maintenance. Use only certified parts. Keep records.