Grain and oil storage tanks require reliable level measurement despite dust, oil mist, foam, and temperature changes. An 80 GHz FMCW non-contact radar sensor is a common choice for these applications. Typical models offer a 0.2-30 m range, +/-3 mm accuracy, and a 3-8 degree beam angle, enabling stable readings in narrow silos and large oil tanks. Process connections include G3/4, 1-1/2 NPT, flange, and sanitary clamp. Wetted parts are usually PTFE or stainless steel to resist grain dust, vegetable oil, and cleaning agents.
Key specifications should cover frequency, range, accuracy, output, power supply, protection, and certification. Standard outputs are 4-20 mA, HART, RS485/Modbus, and relay alarms. A 24 VDC supply with an IP67 housing suits outdoor installations. For flammable oil storage, choose ATEX/IECEx certified models. The sensor should tolerate -40 C to 80 C, pressure up to 1.6 MPa, and condensing atmospheres. Echo processing must reject agitator blades, tank walls, and foam.
Installation affects performance. Mount the radar away from filling streams and keep the antenna perpendicular to the product surface. Use a stilling well or bypass chamber where turbulence is strong. Set the 4 mA and 20 mA points to the tank's empty and full heights, then verify with a manual gauge. Regular cleaning of the antenna prevents dust buildup. A well-matched radar sensor model and clear specification improve inventory accuracy, safety, and operational efficiency. Select the model by tank size and product.