High-temperature environments in shield tunneling place severe demands on crane and trolley positioning systems. When positioning faults occur, symptoms are intermittent: trolley stops short of its target, overshoots the loading point, or reports a position mismatch between encoder and laser sensor. These faults can interrupt muck removal and segment handling, increasing cycle time and safety risk. First separate mechanical, electrical, and thermal causes. Heat can deform rails, reduce grease viscosity, and make encoder couplings slip. VFD overheating may trigger torque derating, while PLC communication errors can corrupt feedback. Maintenance teams should check rail alignment and expansion gaps, verify encoder mounting and cable shielding, clean laser reflectors, and compare absolute and incremental position values. Thermal compensation parameters must match tunnel temperature. Inspect brake release, wheel wear, and trolley guide clearance. Test limit switches and confirm PLC I/O status. Log faults during peak temperature periods to identify trends. During diagnosis, isolate the trolley drive, command slow-speed moves, and record encoder counts at fixed rail marks; repeat after cooling. If it follows load, check rollers and brakes. Preventive measures include temperature sensors near drives and rails, redundant position feedback, scheduled calibration, heat-resistant cables, and forced cooling. A structured fault tree shortens downtime and improves shield tunneling reliability.