Before installation, verify that the flange-mounted turbine flowmeter matches the port material tank nozzle in size, pressure rating, and sealing standard. Shut down the line, drain the tank, and isolate the flange safely. Inspect the meter bore for damage and remove all debris. Fit a suitable gasket, align the meter with the tank flange, and confirm that the flow arrow points in the required direction. Keep the meter axis concentric with the pipe and avoid forced pulling. Use compatible bolts and tighten them diagonally in stages to prevent gasket distortion. Install the required upstream and downstream straight pipe, and support the piping so the meter body carries no extra load. Do not use the meter as a pipe support, and leave enough space for reading and maintenance. On port material tanks, choose a position that allows safe access and does not block tank operations. Connect grounding and signal wiring according to the manual, keeping cables away from hot or vibrating areas. Check flange parallelism and bolt torque with a calibrated wrench. After assembly, perform a pressure leak test and check the zero point. Open the valve slowly, fill the line, and vent trapped air. Keep the flowmeter full of liquid during operation and avoid sudden pressure shocks. Record installation data and verify readings during commissioning. If the fluid contains particles, fit a filter upstream. Routine inspection of flange bolts, gasket condition, and cable seals helps maintain accurate flow measurement and safe tank operation.