Turbine flowmeters are widely used in shield tunneling storage tanks to monitor bentonite slurry, foam, water, and grout. A sudden fault can interrupt backfill and slurry circulation, affecting face stability and construction safety. Common faults include rotor jam from sand or dried slurry, bearing wear, signal loss, cavitation, incorrect viscosity compensation, and electromagnetic interference. Symptoms include no pulse output, unstable readings, low flow alarms, or drift after cleaning. To diagnose the fault, isolate the meter and check tank level, pump pressure, and valve position. Remove the sensor, inspect the rotor for debris, and confirm that the pipe is full. Test coil resistance and cable shielding. Compare the reading with a portable meter or manual volume test. If the rotor spins freely but the signal is weak, check the preamplifier, grounding, and cable connections. For viscous foam or grout, verify the K-factor and viscosity correction. Do not ignore repeated alarms, because they may indicate abrasive wear. Maintenance should include flushing after each shift, filtering abrasive slurry, regular calibration, and checking seals and bearings. Keep spare rotors, sensors, and gaskets for critical tank lines. Use proper flow straighteners and avoid installing the meter near sharp bends or pumps. A scheduled inspection plan reduces downtime and improves flow data reliability in shield tunneling.