Installing an intrinsically safe explosion-proof Graybus cable on a port overhead crane requires strict hazardous-area control. First, confirm the zone classification, gas group, and temperature class; select only certified IS cable, glands, barriers, and junction boxes. Isolate and lock out crane power, then inspect the route for impact, heat, moisture, and salt corrosion. Keep the Graybus cable separate from power cables, using dedicated trays or an independent route with at least 300 mm clearance or a certified barrier. Avoid sharp bends, tight loops, and unnecessary joints. Support the cable at manufacturer-approved intervals, leaving a small service loop at moving parts. Use blue IS identification and label both ends. Terminate with shielded glands; bond the shield and equipotential system exactly as the approved drawing, never creating an unexpected ground loop. Connect the cable to the associated IS barrier or isolator, verify polarity, and keep all unused cores insulated. After installation, check insulation resistance, continuity, shield bonding, and cable anchoring. Test the loop with a certified gas detector before energizing in the hazardous zone. During commissioning, measure IS circuit parameters against the barrier and cable limits. Document route, terminations, test results, and inspection records. Routine checks should cover abrasion, corrosion, loose glands, and shield integrity. This method protects crane control signals and improves safety in port operations.